The maximum power of the PV is twice the rated power. It supports full-power charging and full-power load operation.
It has the function of connecting to the power grid, which effectively improves the energy utilization efficiency.
It is equipped with a dimensional upgrade driving function, enabling a larger load power capacity and support for a wider variety of loads.
It adopts an advanced inverter architecture, which can reliably suppress leakage current and ensure electrical safety.
It can provide bypass output even without a battery, ensuring continuous power supply to critical loads.
It is compatible with lead-acid batteries, lithium batteries, gel batteries, etc.
It has a battery activation function.
It supports a 24V battery input.
| Parameter | HS1022EH24L | HS1022EH48L | HS1033EH24L | HS1033EH48L |
| Battery | ||||
| Battery Voltage | 24Vdc | 48Vdc | 24Vdc | 48Vdc |
| Battery Type | Lead-acid, lithium batteries, gel batteries, etc | |||
| Output | ||||
| Rated Output Power | 2400VA/2200W | 3600VA/3300W | ||
| Parallel Function | N/A | |||
| Rated Output Voltage | 230Vac ±4% | |||
| Rated Output Frequency | 50/60Hz ±0.3(Adaptive) | |||
| Output Waveform | Pure sine wave | |||
| Max Efficiency (Peak) | 93.8% | |||
| Rated Current | 9.6A | 14.3A | ||
| Transfer Time | 10ms (Typical value) | |||
| PV Input | ||||
| Max PV Power | 3600W | |||
| MPPT Voltage Range | 90~500Vdc | |||
| Max Input Voltage | 500Vdc | |||
| Max Charging Current | 100A | 60A | 100A | 60A |
| Mains/Generator Input | ||||
| Max Charging Current | 60A | 30A | 60A | 30A |
| AC Input Voltage Range (UPS mode) | 170~280Vac, ±2% | |||
| Frequency Range | (47-55Hz) ±0.3 / (57-65Hz) ±0.3 | |||
| Battery Input | ||||
| Voltage Range | 20~33Vdc | 40~60Vdc | 20~33Vdc | 40~60Vdc |
| Max Charging Current | 100A | 60A | 100A | 60A |
| Default Charging Current | 30A | |||
| General Parameters | ||||
| Dimension. W*D*H(mm) | 269*100*372 | |||
| Installation Method | Wall-mounted | |||
| Weight (kg) | 7.2 | |||
| Communication Mode | RS485, Optional WIFI/4G | |||
| Protection Function | Over/Under Voltage Protection, Over/Under Frequency Protection, AC Output Short Circuit Protection, AC Output Overload Protection, High/Low Temp Protection | |||
| Operating Environment | ||||
| Operating Ambient Temperature | -10°C~55°C | |||
| Storage Ambient Temperature | -20°C~60°C | |||
| Humidity | 5%~95% Non-condensation | |||
| Altitude | 4000m (>2000m Derating) | |||
| Installation Environment | For indoor use only | |||
| Certifications | ||||
| Certification Standard | IEC/EN 61000-6-1/3, EN 62920, IEC 62109-1, IEC 62109-2, IEC 62321 | |||